holosun eps carry unable to change reticle modes

holosun eps carry unable to change reticle modes

Holosun EPS Carry: Unable to Change Reticle Modes? We Have the Solution!

Hi readers,

Are you facing issues changing reticle modes on your Holosun EPS Carry? Don’t worry, you’re not alone. Many users have encountered the same problem. But fear not! In this comprehensive guide, we’ll explore the possible causes and provide step-by-step solutions to get your Holosun EPS Carry functioning perfectly.

Understanding the Holosun EPS Carry Reticle Modes

The Holosun EPS Carry offers a variety of reticle options, allowing you to customize your shooting experience. The most common reticle modes include:

  • Circle-dot: A circle with a central dot, providing both precision and rapid target acquisition.
  • Dot: A simple, precise aiming point.
  • Multi-dot: Multiple dots arranged in a vertical or horizontal row, facilitating quick target engagement.

Troubleshooting Holosun EPS Carry Unable to Change Reticle Modes

1. Power Issues

  • Check battery: Ensure the battery is properly installed and has sufficient charge.
  • Clean battery terminals: Remove any corrosion or debris from the battery terminals.
  • Reset Holosun: Press and hold the up and down buttons simultaneously for 10 seconds to reset the optic.

2. Button Malfunction

  • Inspect buttons: Examine the buttons for any visible damage or obstructions.
  • Test buttons: Press each button repeatedly to ensure they are functioning properly.
  • Contact Holosun support: If the buttons appear to be faulty, contact Holosun for assistance.

3. Software Issues

  • Update firmware: Holosun periodically releases firmware updates to address bugs and improve functionality. Check the Holosun website for the latest updates.
  • Reset Holosun: As mentioned earlier, resetting the Holosun can often resolve software glitches.

4. Physical Obstruction

  • Remove protective cover: If the Holosun is equipped with a protective cover, remove it to ensure it is not obstructing the buttons.
  • Check for debris: Inspect the optic for any dirt, dust, or debris that could be preventing the buttons from being pressed.

Reticle Mode Change Process

Once you have resolved any underlying issues, changing the reticle mode on your Holosun EPS Carry is simple:

  1. Press and hold the mode button for 3 seconds.
  2. Use the up and down buttons to cycle through the available reticle options.
  3. Release the mode button to confirm your selection.

Compatibility Table for Holosun EPS Carry Reticle Modes

Reticle Mode Compatibility
Circle-dot EPS Carry MRS, EPS Carry RDS
Dot EPS Carry MRS
Multi-dot EPS Carry RDS

Conclusion

If you’re experiencing problems changing reticle modes on your Holosun EPS Carry, follow the troubleshooting steps outlined above. By addressing power issues, button malfunctions, software glitches, and physical obstructions, you should be able to resolve the problem and enjoy the full functionality of your optic.

For more valuable tips and tricks, be sure to check out our other informative articles on Holosun optics and shooting accessories.

FAQ about Holosun EPS Carry Unable to Change Reticle Modes

1. Why can’t I change the reticle modes on my Holosun EPS Carry?

Answer: The Holosun EPS Carry only has one reticle mode: a red dot. It does not have different reticle options.

2. Is there a way to change the reticle color on the Holosun EPS Carry?

Answer: No, the reticle color on the Holosun EPS Carry cannot be changed. It is a red dot sight with a red reticle only.

3. How do I reset the Holosun EPS Carry to factory settings?

Answer: To reset the Holosun EPS Carry to factory settings, press and hold the "+" and "-" buttons simultaneously for 5 seconds. The reticle will flash three times to indicate the reset is complete.

4. What is the battery life of the Holosun EPS Carry?

Answer: The Holosun EPS Carry has a battery life of approximately 50,000 hours on the lowest brightness setting. The battery life will vary depending on the brightness level used.

5. How do I change the battery on the Holosun EPS Carry?

Answer: To change the battery on the Holosun EPS Carry, use the included Torx wrench to remove the battery cap. Replace the old battery with a new CR1632 battery, positive side up. Tighten the battery cap to secure it.

6. What is the warranty on the Holosun EPS Carry?

Answer: The Holosun EPS Carry has a limited lifetime warranty.

7. How do I adjust the brightness on the Holosun EPS Carry?

Answer: To adjust the brightness on the Holosun EPS Carry, press the "+" or "-" buttons on the side of the sight. The brightness level will incrementally increase or decrease.

8. How do I sight in the Holosun EPS Carry?

Answer: To sight in the Holosun EPS Carry, use the supplied Torx wrench to adjust the elevation and windage screws. Turn the screws clockwise to adjust the reticle up or left, and counterclockwise to adjust the reticle down or right.

9. What is the MOA of the Holosun EPS Carry?

Answer: The Holosun EPS Carry has a 2 MOA dot.

10. What is the mounting plate for the Holosun EPS Carry?

Answer: The Holosun EPS Carry comes with a proprietary mounting plate that is specific to this sight.